Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/sites/launch-tech.net/index/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the electro-extensions domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/sites/launch-tech.net/index/wp-includes/functions.php on line 6170
LAUNCH X431 EM101N EV Oscilloscope and Multimeter 2-channel for X431 PAD V, PAD VII – launch-tech.net

WordPress database error: [Server shutdown in progress]
SELECT DISTINCT t.term_id FROM wp_terms AS t INNER JOIN wp_term_taxonomy AS tt ON t.term_id = tt.term_id INNER JOIN wp_term_relationships AS tr ON tr.term_taxonomy_id = tt.term_taxonomy_id WHERE tt.taxonomy IN ('product_cat') AND tr.object_id IN (6499) ORDER BY tt.parent DESC


Warning: mysqli_real_connect(): (HY000/2002): Connection refused in /www/sites/launch-tech.net/index/wp-includes/class-wpdb.php on line 1988

LAUNCH X431 EM101N EV Oscilloscope and Multimeter 2-channel for X431 PAD V, PAD VII


$395.00
 Free Shipping

Launch EM101N EV Oscilloscope & Multimeter

The detection and maintenance of the power system is important for new energy vehicles. By viewing the waveform diagram, the maintenance progress can be improved. This product integrates the functions of a multimeter and a dual-channel oscilloscope, which can be used for two purposes. The brand-new diagnostic APP is user-friendly, easy to use and convenient, supports the function of saving and opening waveforms locally.

Features

1. Combined with the characteristics of dual-channel oscilloscope and multimeter.

2. The anti-fall rubber sleeve increases the protection of the product, and the unique fuse plug-in design is convenient for replacement.

3. With X-431 diagnostic tool, it can be connected wirelessly or in wired mode, which can be freely selected.

4. With X-431 diagnostic tool, the new UI design supports three display modes, which can be freely switched.

5. Needle sets, multimeter pens, alligator clips, oscilloscope channel test leads, etc. are all available.

Specification

 

  DC Voltage   Automatic range, test range: ±600V
  AC Voltage   Automatic range, test range: ±600V
  DC Current   Automatic range, test range: ±10A

(It is necessary to connect an external sensor for large range current.)

  AC Current   Automatic range, test range: ±10A. Average value measurement

(It is necessary to connect an external sensor for large range current.)

  Resistance   Automatic range, test range: 0~6MΩ
  On and off   Tweet when less than 30Ω
  Diode   0.5V—2.0V
  Battery Capacity   3100mAh
  Bandwidth   10MHz
  Channel   Two analog channels
  Real-time Sampling Rate (Max)   50MHz/s
  Time Base Range   1us/div~10s/div, step by 1~2~5 times
  Sampling Mode   Normal sampling, peak detection, average
  Buffer Memory   1M
  Input Coupling   DC, AC, grounded
  Input Resistance   1MΩ±2%, Parallel with 15pF±5pF
  Vertical Sensitivity   2mV/div~5V/div
  Vertical Resolution   8bits
  Maximum Input Voltage   40V  peak value(DC + AC peak value)
  Probe Attenuation Factor   1X, 10X, 100X(probe support required)
  Trigger Type   Edge trigger, pulse width trigger
  Trigger Mode   Auto, Normal, Single
  Automatic Measurement   Peak-to-peak value, Average value, Maximum value, Minimum value, Top value,  Bottom value, Frequency, Period
SKU: EM101N Category:
Weight 5 kg

Deprecated: preg_match_all(): Passing null to parameter #2 ($subject) of type string is deprecated in /www/sites/launch-tech.net/index/wp-includes/media.php on line 1893

Deprecated: preg_split(): Passing null to parameter #2 ($subject) of type string is deprecated in /www/sites/launch-tech.net/index/wp-includes/formatting.php on line 3492

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “LAUNCH X431 EM101N EV Oscilloscope and Multimeter 2-channel for X431 PAD V, PAD VII”

There are no reviews yet.